Role of ultrasonography for assessing optimal placement of supraglottic airway devices: A review of literature


Department of Onco-Anaesthesia and Palliative Medicine, Dr BRAIRCH, All India Institute of Medical Sciences, New Delhi, India

Correspondence Address:
Dr. Rakesh Garg
Room No. 139, First Floor, Department of Onco-Anaesthesia and Palliative Medicine, Dr BRAIRCH, All India Institute of Medical Sciences, Ansari Nagar, New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ARWY.ARWY_11_20

Rights and Permissions

Supraglottic airway devices (SADs) have revolutionised perioperative airway management. These devices have contributed significantly to airway management, especially in the context of anticipated or unanticipated difficult airway, thereby decreasing airway-related morbidity. The use of these devices is now accepted even for positive pressure ventilation due to better seal and modifications (such as a double cuff or cuff material) preventing gastric insufflation with lesser chances of regurgitation. The quality of seal depends on how accurately the cuff matches the dimensions of the laryngeal inlet. Various methods and techniques are used for confirming the optimal placement of SADs with variable success rate. Evaluation based on conventional clinical tests is most commonly used for assessing the correct placement of SADs. However, clinical tests have been associated with limited outcome as they may not definitely be able to detect improper placement of SAD. Malpositioning may increase the incidence of complications such as altered airway dynamics, gastric insufflation, regurgitation and aspiration of gastric contents. The accuracy of these tests to identify malposition has been questioned by recent studies where fibreoptic evaluation of position of SAD identified many unacceptable placements which had been considered acceptable on the basis of clinical tests. Another limitation of these tests is that they fail to provide anatomic evidence of optimal SAD placement. Thus, other methods are required to confirm SAD position to avoid adverse events related to the airway. This review elaborates on the use of ultrasound to assess the optimal placement of supraglottic airway devices.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed568    
    Printed33    
    Emailed0    
    PDF Downloaded115    
    Comments [Add]    

Recommend this journal